-10°C Vertical Refrigerated Circulating Bath 6-50L | PID Laboratory Circulator with External Circulation
The BO-DC -10°C Series is a vertical refrigerated circulating bath for laboratory cooling, heating and temperature-control applications. It operates from -10 to 100°C, offers 6–50 L bath capacities, and supports both internal and external circulation. PID control with Pt100 temperature sensing provides temperature stability up to ±0.05°C, with 10 L/min external pump flow for connected
Số mục :
BDC10Đặt hàng (MOQ) :
1Giá :
USD:504Nguồn gốc sản phẩm :
ChinaMàu sắc :
WhiteCảng vận chuyển :
Xia MenThời gian dẫn :
15DaysCân nặng :
T/TUse the BO-DC -10°C Series as a controlled-temperature liquid bath or as a circulation source for compatible laboratory equipment. The upright enclosure combines the working chamber, controller and refrigeration assembly in one unit.
| Temperature Range | -10 to 100°C |
|---|---|
| Temperature Stability | ±0.05°C |
| Temperature Control | PID with Pt100 sensing |
| Display Resolution | 0.1°C |
| External Pump Flow | 10 L/min |
| Timer | 0–9999 min |
| Power Supply | 220 V, 50 Hz |
| Circulation | Internal & External |
Compare capacity, chamber dimensions and opening size to match the space required by your samples or fixtures.
| Model | Capacity | Inner Tank Size | Opening Size | Cooling Capacity |
|---|---|---|---|---|
| BO-DC1006 | 6 L | 200 × 200 × 165 mm | 180 × 140 mm | 800 W |
| BO-DC1010 | 10 L | 280 × 200 × 180 mm | 180 × 140 mm | 1200 W |
| BO-DC1015 | 15 L | 300 × 280 × 180 mm | 260 × 220 mm | 1800 W |
| BO-DC1020 | 20 L | 400 × 280 × 180 mm | 260 × 220 mm | 2300 W |
| BO-DC1030 | 30 L | 400 × 280 × 250 mm | 260 × 220 mm | 3000 W |
| BO-DC1050 | 50 L | 500 × 370 × 300 mm | 350 × 300 mm | 4300 W |
Cooling capacity values are based on current product specification data. Test temperature and test conditions should be confirmed for engineering selection.
For direct bath use, fluid circulates within the chamber to maintain an even temperature around immersed samples. For external use, temperature-controlled fluid leaves the outlet, passes through the connected equipment and returns to the inlet. Both circulation connections are on the left side of the vertical unit.
Typical work includes conditioning samples before measurement, maintaining viscometer test temperatures, cooling rotary evaporator condensers and controlling reactor-jacket fluid. These uses support routine research and quality-control workflows.
Upper and lower temperature-deviation alarms identify operation outside the set limits; a sensor-fault alarm reports temperature-sensing issues. The refrigeration circuit includes overheat and overcurrent protection, plus a compressor restart delay.